By the Numbers
By the Numbers: Heat Pump COP â Turn Efficiency Into kWh and Running Cost
Learn how heat pump COP converts heating demand into electricity use and running costs. Follow worked kWh examples and see why real efficiency can vary.
The International Energy Agency (IEA) says global heat pump sales fell by about 2% in 2025, while Europeâs annual sales rose by 11% (the first year of growth since 2022) in its Global Energy Review 2026.
Those market stats are interesting, but the consumer-facing question is usually more practical: if a heat pump is âefficientâ, what does that mean in electricity use (kWh) and estimated running cost?
This article uses a simple COP â kWh chain and the appliance running cost calculator to turn âefficiencyâ into a number you can sanity-check. It is an estimate and not advice.
The story number
From the IEAâs Global Energy Review 2026 heat pumps section:
- Global heat pump sales: about -2% in 2025
- Europe annual heat pump sales: +11% in 2025
The number to run
The key idea is COP (Coefficient of Performance):
- COP = heat output á electricity input
So if you know (or assume) how much useful heat you need, electricity use is:
- electricity (kWh) = heat needed (kWh) á COP
That single line explains why âCOP 3â is a big deal: it turns 30 kWh of heat into about 10 kWh of electricity.
Run the numbers (daily heating-demand examples)
Pick an illustrative daily heat demand and a heating runtime window:
- Useful heat needed: 30 kWh per day (illustrative)
- Heating runtime: 10 hours per day (illustrative)
Now compare different COP assumptions:
| Scenario | COP | Useful heat (kWh/day) | Electricity (kWh/day) | Avg electric power over 10h (kW) |
|---|---|---|---|---|
| âLower COPâ example | 2.0 | 30 | 15.0 | 1.50 |
| âMid COPâ example | 3.0 | 30 | 10.0 | 1.00 |
| âHigher COPâ example | 4.0 | 30 | 7.5 | 0.75 |
To translate that into money, multiply electricity (kWh) by your electricity unit rate.
For example, at an illustrative rate of 30p/kWh:
- COP 2.0: 15.0 kWh/day Ă ÂŁ0.30 â ÂŁ4.50/day
- COP 3.0: 10.0 kWh/day Ă ÂŁ0.30 â ÂŁ3.00/day
- COP 4.0: 7.5 kWh/day Ă ÂŁ0.30 â ÂŁ2.25/day
Thatâs a ÂŁ1.50/day difference between COP 2 and COP 3 in this worked example â around ÂŁ45/month if the pattern held every day.
How to use the appliance running cost calculator for this
The appliance running cost calculator works with âwattsâ and âhoursâ.
To approximate the COP math in that format:
1) Decide your electricity use (kWh/day) from `heat á COP`. 2) Choose a runtime window (hours/day). 3) Convert to average power:
- average kW = kWh á hours
- average watts = average kW Ă 1,000
Using the COP 3 example above:
- Electricity needed: 10 kWh/day
- Over: 10 hours/day
- Average power: 1 kW = 1,000 W
Enter 1,000 W and 10 hours (plus your unit rate) to get a comparable daily cost estimate.
What the result means (and what it doesnât)
This framing is useful because:
- It separates âhow much heat you needâ from âhow efficiently you make itâ.
- It shows why small changes in COP can matter over a season.
But it does not tell you what your real COP will be or what your bill âwillâ be.
Try your own numbers
Use the appliance running cost calculator with:
- Your assumed average power (watts) and runtime (hours)
- Your electricity unit rate (p/kWh or your local currency per kWh)
If you want to do the COP step explicitly first, you may find these useful:
- Unit converter (kW â W)
- Percentage calculator (for âwhat if COP is 15% higher?â sensitivity)
Caveats and source notes
- The IEA figures are about heat pump sales (market trends), not household running costs.
- COP varies with outside temperature, flow temperature, system design, home insulation, and how the system is run. Seasonal performance is often lower than a lab/test COP.
- âUseful heat needed per dayâ varies hugely by climate, dwelling type, insulation, floor area, thermostat setting, and occupancy.
Source: IEA Global Energy Review 2026, âTechnology: Heat pumpsâ.
Reader questions
Is COP the same as what Iâll get at home?
Not necessarily. COP varies over time, and many sources quote seasonal performance (which averages over different conditions). Use this post as a way to understand the math, not as a promise.
Why use âheat neededâ instead of âheat pump wattsâ?
Because the useful heat demand is the thing youâre trying to satisfy. COP tells you how much electricity you need to deliver that heat.
Is this advice on whether I should buy a heat pump?
No. Itâs an educational worked example to explain the COP â kWh â cost chain.